• Link to X
  • Link to LinkedIn
  • Link to Mail
  • ABOUT UI
    • Business Partners
    • Careers
    • Contact Us
    • News & Press
    • Our Team
    • Press Releases
    • Branding Guidelines
  • CONTACT
Uptime Institute Blog
  • Journal
    • Journal Home
    • Executive
    • Operations
    • Design
  • AI Services
    • AI Infrastructure Advisory
  • Tier Certification
    • Overview
    • Design
    • Construction
    • Operations
    • Tier Gap Analysis
    • Prefabricated/Modular
    • Tier Certifications List
  • Professional Services
    • Overview
    • Infrastructure Services
    • Management and Operations Services
    • Energy and Sustainability Services
    • Consulting Services
  • Education
    • Education Framework
    • Course Calendar
    • Competency & Confidence Assessments
    • Private Education
    • Graduate Roster
  • Events
    • Industry Events
    • Leadership Events
    • Network Events
  • Network
    • Overview
    • Network Calendar
    • Network Roster
    • Request Corporate Access
    • Request Guest Access
    • Uptime Network Portal
  • Intelligence
  • Clients
    • Client Stories
  • Resources
    • Data Center Industry Surveys
    • Ebooks
    • Journal Blog
    • Product Datasheets
    • Research & Reports
    • Tier Specification Documents
    • Tools
    • Webinars
  • Click to open the search input field Click to open the search input field Search
  • Menu Menu
Blog - Latest News

LinkedIn’s Oregon Data Center Goes Live, Gains EIT Stamp of Approval

December 8, 2016/in Executive, Operations/by Kevin Heslin

Uptime Institute recently awarded its Efficient IT (EIT) Stamp of Approval to LinkedIn for its new data center in Infomart Portland, signaling that the modern new facility had exceeded extremely high standards for enterprise leadership, operations, and computing infrastructure. These standards are designed to help organizations lower costs and increase efficiency, and leverage technology for good stewardship of corporate and environmental resources. Uptime Institute congratulates LinkedIn on this significant accomplishment.

Sonu Nayyar, VP of Production Operations & IT for LinkedIn, said “Our newest data center is a big step forward, allowing us to adopt a hyperscale architecture while being even more efficient about how we consume resource. Uptime Institute’s Efficient IT Stamp of Approval is a strong confirmation that our management functions of IT, data center engineering, finance, and sustainability are aligned. We look forward to improving how we source energy and ultimately reaching our goal of 100 percent renewable energy.”

John Sheputis, President of Infomart Data Centers, said, “We knew this project would be special from the moment we began collaborating on design. Efficiency and sustainability are achieved through superior control of resources, not sacrificing performance or availability. We view this award as further evidence of Infomart’s long-term commitment to working with customers to create the most sustainable IT operations in the world.”

LinkedIn expressed its enthusiasm about both this new project and the Efficient IT Stamp of Approval in the LinkedIn Engineering blog post below.

LinkedIn’s Oregon Data Center Goes Live

By Shawn Zandi and Mike Yamaguchi

image001Earlier this year we announced Project Altair, our massively scalable, next-generation data center design. We also announced our plans to build a new data center in Oregon, in order to be able to more reliably deliver our services to our members and customers. Today, we’d like to announce that our Oregon data center, featuring the design innovations of Project Altair, is fully live and ramped. The primary criteria when selecting the Oregon location were: procuring a direct access contract for 100% renewable energy, network diversity, expansion capabilities, and talent opportunities.

image004LinkedIn’s Oregon data center, hosted by Infomart, is the most technologically advanced and highly efficient data center in our global portfolio, and includes a sustainable mechanical and electrical system that is now the benchmark for our future builds. We chose to utilize the ChilledDoor from MotivAir, a rear door heat exchanger neutralizing the heat closer to the source. The advanced water side economizer cooling system communicates with outside air sensors to utilize Oregon’s naturally cool temperatures, instead of using energy to create cool air. Incorporating efficient technologies such as these enables our operations to run a PUE (Power Usage Effectiveness) of 1.06 during full economization mode.

image006Implementing the Project Altair next-generation data center design enabled us to move to a widely distributed non-blocking fabric with uniform chipset, bandwidth, and buffering characteristics in a minimalistic and elegant design. We encourage the most minimalistic and simplistic approaches in infrastructure engineering because they are easy to understand and hence easier to scale. Moving to a unified software architecture for the whole data center allows us to run the same set of tools on both end systems (servers) and intermediate systems (network).

The shift to simplification in order to own and control our architecture motivated us to also use our own 100G Ethernet open switch platform, called Project Falco. The advantages of using our own software stack are numerous: faster time to market, uniformity, simplification in feature requirements as well as deployment, and controlling our architecture and scale, to name a few.

In addition to the infrastructure innovation mentioned earlier, our Oregon data center has been designed and deployed to use IPv6 (next generation internet protocol) from day one. This is part of our larger vision to move our entire stack to IPv6 globally in order to retire IPv4 in our existing data centers. The move to IPv6 enabled us to run our application stack and our private cloud, LPS (LinkedIn Platform as a Service), without the limitations of traditional stacks.

As we moved to a distributed security system by creating a distributed firewall and removing network load balancers, the process of preparing and migrating our site to the new data center became a complicated task. It required significant automation and code development, as well as changes to procedures and software configurations, but ultimately reduced our infrastructure costs and gave us additional operational flexibility.

Our site reliability engineers and systems engineering teams introduced a number of innovations in deployment and provisioning, which allowed us to streamline the software buildout process. This, combined with zero touch deployment, resulted in a shorter timeline and smoother process for bringing a data center live than we’ve ever achieved before.

YouTube Link

Acknowledgements

We’re delighted to participate in the growth of Oregon as a next-generation sustainable technology center. The Uptime Institute has recognized LinkedIn with an Efficient IT award for our efforts! This award evaluates the management processes and organizational behaviors to achieve lasting reductions in cost, utilities, staff time, and carbon emissions for data centers.

The deployment of our new data center was a collective effort of many talented individuals across LinkedIn in several organizations. Special thanks to the LinkedIn Data Center team, Infrastructure Engineering, Production Engineering and Operations (PEO), Global Ops, AAAA team, House Security, SRE organization, and LinkedIn Engineering.

Share this:

  • Share on Facebook (Opens in new window) Facebook
  • Share on X (Opens in new window) X
  • Share on LinkedIn (Opens in new window) LinkedIn
  • Share on Reddit (Opens in new window) Reddit
  • Share on WhatsApp (Opens in new window) WhatsApp
  • Email a link to a friend (Opens in new window) Email
Tags: Altair, Data Center, Data Center Energy Efficiency, Data Center Facilities Management, Data Center Operations, Efficient IT, Efficient IT Stamp of Approval, Falco, Infomart, Infrastructure, LinkedIn, Networking, Uptime Institute
https://journal.uptimeinstitute.com/wp-content/uploads/2016/12/linkedinfinal.jpg 475 1200 Kevin Heslin https://journal.uptimeinstitute.com/wp-content/uploads/2022/12/uptime-institute-logo-r_240x88_v2023-with-space.png Kevin Heslin2016-12-08 08:12:292018-07-12 08:56:17LinkedIn’s Oregon Data Center Goes Live, Gains EIT Stamp of Approval
You might also like
Global PUEs — are they going anywhere? Global PUEs — are they going anywhere?
Performance expectations of liquid cooling need a reality check Performance expectations of liquid cooling need a reality check
Retainers Improve the Effectiveness of IEC Plugs
Data center staff on-site: engineering specialists or generalists?
DLC will not come to the rescue of data center sustainability DLC will not come to the rescue of data center sustainability
Open19 is About Improving Hardware Choices, Standardizing Deployment
Bank of Canada Achieves Operational Excellence
Separation of Production vs. Non-Production IT Non-production IT can hinder mission-critical operations

Content Categories

  • Journal Home
  • Executive
  • Operations
  • Design

Subscribe to Journal via Email

Enter your email address to subscribe to Uptime Institute Journal and receive notifications of new articles by email.

  • Recent

Tags

Accredited Tier Designer (9) AI (24) artificial intelligence (19) ATD (10) Carbon Emissions (7) Climate Change (13) Cloud (23) Cloud Computing (17) Cloud Costs (15) Cloud Infrastructure (29) Cloud Migration (8) Colocation (7) cooling (13) Data Center (261) Data Center Availability (40) Data Center Cooling (13) Data Center Design (45) Data Center Disaster Recovery (7) Data Center Energy Efficiency (34) Data Center Facilities Management (43) Data Center Operations (67) data center power (9) Data Center Staffing (19) DCIM (9) digital Infrastructure (126) energy (8) Energy Efficiency (38) Environmental Sustainability (18) IT (7) IT Efficiency (17) IT Outages (10) M&O (6) outages (12) Public Cloud (7) PUE (10) Regulations (25) Resiliency (9) security (7) Sustainability (34) Sustainability Reporting (7) Tier Certification (26) Tier Certification Constructed Facility (16) Uptime Institute FORCSS (6) Uptime Institute Network (13) Uptime Institute Symposium (6)
© 2014-2025 Uptime Institute, LLC All rights reserved.
  • Link to X
  • Link to LinkedIn
  • Link to Mail
Link to: Airline Outages FAQ: How to Keep Your Company Out of the Headlines Link to: Airline Outages FAQ: How to Keep Your Company Out of the Headlines Airline Outages FAQ: How to Keep Your Company Out of the Headlines Link to: When an Australian Government Department Required Operational Sustainability, Metronode Delivered Link to: When an Australian Government Department Required Operational Sustainability, Metronode Delivered When an Australian Government Department Required Operational Sustainability,...
Scroll to top Scroll to top Scroll to top